Installation of a new AeroDry Gas Hood targeting to increase production
Replacement of the existing Fourdrinier by a Crescent Former model HCF 1225 with the objective to increase the quality of the double ply toilet tissue
Installation of a new Approach Flow System in order to guarantee a higher stability in the process and a smaller basis weight variation
Former Section with a Ø 1225 mm Former Roll, new Ø466 Guide Rolls mm and frames with the porter-bar (front lift) design
High efficiency Gas Hood with working temperature 450°
Approach Flow with the double dilution concept
Machine speed increased from 710 m/min to 1000 m/min
The client saw a significant improvement on the double ply tissue quality, besides an improvement on the cross machine basis weight profile
Hergen’s Formers, click here.
Hergen’s AeroDry Hoods, click here.
Hergen’s Approach Flow Systems, click here.